Título : Evaluación de concentraciones de plomo en sangre al personal del área de combustible y armamento de la Armada del Ecuador
Autor : Laínez Silvestre, Cristopher Alexis
Muñoz Reyes, Julissa María
Tutor(es): Mariscal Santi Walter
Palabras clave : ABASTECIMIENTO
VOLTAMERIA
ANÓDICA
PLOMO
CONCENTRACIONES
Fecha de publicación : 2018
Editorial : Universidad de Guayaquil. Facultad de Ciencias Químicas
Tipo: bachelorThesis
Resumen : El analizador portátil con voltametria anódica llamado LeadCare II, evalúa los niveles de plomo en sangre, los pacientes de estudios fueron 240, entre las edades de 33 a 40 años, con un tiempo laboral de uno a dos años, acudieron a su diagnós- tico anual durante los meses de Enero hasta Junio, en la Dirección de Sanidad de la Armada del Ecuador, los análisis estadísticos se realizan determinando el pro- medio, mediana, moda, valor mínimo, máximo, desviación estándar y varianza con los factores de edad, tiempo laboral y concentración de plomo en sangre, 18 paciente presentaron elevadas concentraciones de plomo en sangre, los análisis estadísticos presentaron valor promedio 4,64; con una mediana de 3,30, una me- diana de 3,30, una moda de 3,30, valor mínimo registrado de 3,30 y un valor má- ximo de 16.70 con una desviación estándar de 2,71. Se conoció las concentracio- nes exactas de plomo que contiene cada paciente por medio del analizador Lead- Care II.
The portable analyzer with anodic voltametry called LeadCare II, evaluates the levels of lead in blood, the study patients were 240, between the ages of 33 to 40 years, with a working time of one to two years, they attended their annual di- agnosis during the months of January to June, in the Directorate of Health of the Ecuadorian Navy, statistical analyzes are performed by determining the average, median, mode, minimum value, maximum, standard deviation and variance with the factors of age, working time and concentration of lead in blood, 18 patients presented high concentrations of lead in blood, the statistical analysis showed an average value of 4.64; with a median of 3.30, a median of 3.30, a mode of 3.30, minimum registered value of 3.30 and a maximum value of 16.70 with a standard deviation of 2.71. The exact concentrations of lead contained in each patient were known through the LeadCare II analyzer
Descripción : Pdf
URI : http://repositorio.ug.edu.ec/handle/redug/35315
Aparece en las colecciones: Tesis - Químicos Farmacéuticos

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
BCIEQ-T-0334 Laínez Silvestre Cristopher Alexis; Muñoz Reyes Julissa María.pdfBCIEQ-T-0334 Laínez Silvestre Cristopher Alexis; Muñoz Reyes Julissa María4,83 MBAdobe PDFVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.