Por favor, use este identificador para citar o enlazar este ítem: http://repositorio.ug.edu.ec/handle/redug/44263
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorRegalado Camacho, Erika Salomé-
dc.date.accessioned2019-10-03T19:44:11Z-
dc.date.available2019-10-03T19:44:11Z-
dc.date.issued2019-09-10-
dc.identifier.other3095-
dc.identifier.urihttp://repositorio.ug.edu.ec/handle/redug/44263-
dc.descriptionpdfes_ES
dc.description.abstractLa constante evolución de las Resinas se ha basado a los diferentes problemas suscitados tanto en los protocolos clínicos como molestias para el paciente como Microfiltraciones, sensibilidad post-operatoria, caries recurrentes, etc. Siendo la causa principal el Factor C. A partir de aquello se incrementaron al mercado las Resinas Bulk Fill obviando los diferentes problemas mencionados. El objetivo del presente trabajo es determinar la Resistencia Flexural más conveniente para la restauración de piezas dentarias entre dos Tipos de Resinas: Tetric-N Ceram Bulk Fill Y Filtek Bulk Fill, para ser utilizadas en la Facultad Piloto de Odontología. Se realizó un estudio de 30 especímenes de Resina (Tetric N- Ceram Bulk Fill y Filtek Bulk Fill) de acuerdo a la norma ISO 4049 con las siguientes dimensiones: 25 mm; 2 mm; 4 mm. Se dividió en dos grupos de 15 especímenes según la marca correspondiente, con el mismo protocolo de fotocurado. Las muestras fueron almacenadas en agua destilada a 37° por 48 horas, luego fueron sometidos a pruebas de flexión en tres puntos de los especímenes en la Maquina de Ensayos Universal (MARSHALL PS25) con una velocidad de 1.7mm/min determinando la Flexión antes que el material se Fracture. Posteriormente estos valores fueron expresados en Megapascales. Los datos fueron analizados estadísticamente de acuerdo al Software de T-Student, con un p > 0.05 y el Software Shapiro Wilk. Los Resultados obtenidos se realizó mediante gráficos y tablas. Concluyendo que la Resina Filtek Bulk Fill obtuvo una resistencia Flexural más significativa que Tetric N-Ceram Bulk Fill.es_ES
dc.description.abstractThe constant evolution of Resins has been based on the different problems raised in both clinical protocols and discomfort for the patient such as Microfiltrations, post-operative sensitivity, recurrent cavities, etc. Factor C is the main cause. From this bulk fill resins were increased to the market, ignoring the different problems mentioned.The objective of this work is to determine the most suitable Flexural Resistance for the restoration of tooth parts between two types of Resins: Tetric-N Ceram Bulk Fill and Filtek Bulk Fill, to be used in the Facultad Piloto de Odontología 2019. A study was carried out on 30 resin specimens (Tetric N- Ceram Bulk Fill and Filtek Bulk Fill) in accordance with ISO 4049 with the following dimensions: 25 mm; 2 mm; 4 mm. It was divided into two groups of 15 specimens according to the corresponding mark, with the same photocuring protocol. The samples were stored in distilled water at 37 o for 48 hours, then subjected to bending tests at three points of the specimens in the Universal Test Machine (MARSHALL PS25) with a speed of 1.7mm/min determining the Flexion before the material is Fracture. Subsequently these values were expressed in Megapascales. The data was statistically analyzed in accordance with the T-Student Software, with a p > 0.05 and the Shapiro Wilk Software. The Results obtained were made using charts and tables. Concluding that Filtek Bulk Fill Resin obtained a more significant Flexural resistance than Tetric N-Ceram Bulk Fill.es_ES
dc.language.isospaes_ES
dc.publisherUniversidad de Guayaquil. Facultad Piloto de Odontologíaes_ES
dc.rightsopenAccesses_ES
dc.subjectPOLIMERIZACIONes_ES
dc.subjectRESINAS COMPUESTASes_ES
dc.subjectOPERATORIA DENTALes_ES
dc.titleResistencia flexural entre dos tipos de resina tetric-n ceram bulk fill y filtek bulk fill 3mes_ES
dc.typebachelorThesises_ES
dc.contributor.tutorProaño Yela, Patricio-
Aparece en las colecciones: Tesinas - Odontología

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
REGALADOericka.pdf30957,5 MBAdobe PDFVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.