Exactitud y precisión del estudio diferencial de leucocitos utilizando la técnica manual y un contador automático en pacientes entre 25 y 40 años del Hospital de Infectología y Teodoro Maldonado Carbo

dc.contributor.authorMonge Moreno, Adriana
dc.contributor.tutorLuna Estrella Zoila Bella
dc.date.accessioned2014-02-10T20:11:19Z
dc.date.available2014-02-10T20:11:19Z
dc.date.issued2004
dc.descriptionPdfes_ES
dc.description.abstractLa presente tesis se realiza basándose en una exactitud y precisión del estudio referencial de leucocitos utilizando la técnica manual y un contador automático en pacientes entre 25 y 40 años del Hospital de Infectología y Teodoro Maldonado Carbo; durante el período de Enero a Mayo del 2004, se efectuaron determinaciones en pacientes ambulatorios de emergencia y hospitalización. Los resultados obtenidos en base a técnicas y procedimientos de análisis estandarizados para hematología, utilizando uno de los parámetros que se encuentra en una citometría hemática como es el estudio diferencial de leucocitos utilizando técnica manual y un contador automático (SYSMEX KX-21N). Se analizaron 101 muestra utilizando técnica en tinción en placa y contador automático, de los cuales el 63% de los pacientes pertenecen al sexo masculino y el 37% al sexo femenino; correspondiendo en un 31% a pacientes entre 25 a 30 años, 25% entre 31 a 35 años y un 44% a pacientes de 36 a 40 años. Según el valor de neutrófilos o segmentados encontramos que el 72% presenta niveles normales de acuerdo al contador automático a diferencia del 25% que se encuentran en la técnica de tinción en placa, en niveles altos hallamos un 0% en el contador automático, en técnica manual un 24%, en niveles bajos tenemos que el 19% pertenecen al contador automático y un 51% fue encontrado en técnica manual, además se obtuvo un 10% sin lectura en el contador automático, esto demuestra que existen diferencias significativas. Según el valor de los linfocitos tenemos en valores altos el 4% en el contador automático, el 60% de acuerdo a la técnica de tinción en placa; en valores bajos se obtuvo un 0% por técnica del contador automático y un 16% según técnica manual, en valores normales tenemos que el 95% en contador automático y un 24% en técnica manual, existiendo una marcada diferencia entre ambas técnicas. De acuerdo al MXD que es un parámetro del contador automático que encierra a todas las células diferentes de los neutrófilos y linfocitos, para lo cual fue necesario agrupar los resultados de todas las células (neutrófilos en cayados, eosinófilos, basófilos y monocitos) que arrojaron la técnica manual, por lo tanto se obtuvo: un 13% en contador automático y el 48% en técnica manual en valores altos, el 78% según contador automático y el 59% en tinción en placa en valores normales; el 0% en contador automático y el 56% en técnica manual correspondientes a valores bajos, y por último, el contador automático dio el 9% de valores sin lectura. Encontrándose diferencias entre ambas técnicas, las cuales deben ser reevaluadas mediante la utilización de la técnica manual, que nos permitan obtener diagnósticos seguros y confiables que involucran tanto a pacientes, analistas y médicos.es_ES
dc.description.abstractThe present thesis is carried out being based on an accuracy and precision of the study referential of leukocytes using the manual technique and an automatic accountant in patients between 25 and 40 years of the Hospital of Infectología and Teodoro Maldonado Carbo; during the period of January to May of the 2004, determinations were made in ambulatory patients of emergency and hospitalization. The results obtained based on technical and analysis procedures standardized for hematology, using one of the parameters that is in a citometría hemática like it is the differential study of leukocytes using manual technique and an automatic accountant (SYSMEX KX-21N). They were analyzed 101 sample using technique in tint in badge and automatic accountant, of which 63% of the patients belongs to the masculine sex and 37% to the feminine sex; corresponding in 31% to patients among 25 to 30 years, 25% among 31 to 35 years and 44% to patient of 36 to 40 years. According to the neutrófilos value or segmented we find that 72% presents normal levels according to the automatic accountant contrary to 25% that are in the tint technique in badge, in high levels we find 0% in the automatic accountant, in manual technique 24%, in levels first floor has that 19% belongs to the automatic accountant and 51% it was found in manual technique, 10% was also obtained without reading in the automatic accountant, this demonstrates that significant differences exist. According to the value of the lymphocytes we have in high values 4% in the automatic accountant, 60% according to the tint technique in badge; in values first floor 0% was obtained by the automatic accountant's technique and 16% according to manual technique, in normal values we have that 95% in automatic accountant and 24% in manual technique, existing a marked difference among both techniques. According to the MXD that is the automatic accountant's parameter that contains to all the cells different from the neutrófilos and lymphocytes, for that which was necessary to contain the results of all the cells (neutrófilos in shepherd's crooks, eosinófilos, basófilos and monocitos) that threw the manual technique, therefore it was obtained: 13% in automatic accountant and 48% in manual technique in high values, 78% according to automatic accountant and 59% in tint in badge in normal values; 0% in automatic accountant and 56% in manual technique corresponding to values first floor, and lastly, the automatic accountant gave 9% of values without reading. Being differences between both techniques, which should be re-evaluated by means of the use of the manual technique that you/they allow us to obtain sure and reliable diagnoses that involve patients, analysts and doctors so much.es_ES
dc.identifier.urihttp://repositorio.ug.edu.ec/handle/redug/3129
dc.language.isospaes_ES
dc.publisherUniversidad de Guayaquil. Facultad de Ciencias Químicases_ES
dc.rightsopenAccesses_ES
dc.subjectLEUCOCITOes_ES
dc.subjectCITOMETRIA TEMÁTICAes_ES
dc.subjectHEMATOLOGIAes_ES
dc.titleExactitud y precisión del estudio diferencial de leucocitos utilizando la técnica manual y un contador automático en pacientes entre 25 y 40 años del Hospital de Infectología y Teodoro Maldonado Carboes_ES
dc.typebachelorThesises_ES
Archivos
Bloque original
Mostrando 1 - 4 de 4
Cargando...
Miniatura
Nombre:
PORTADA ADRIANA 1amonge.pdf
Tamaño:
60.8 KB
Formato:
Adobe Portable Document Format
Descripción:
Adrimonge.portada-1.pdf
Cargando...
Miniatura
Nombre:
Tesis de Adriana Mongeccqq.pdf
Tamaño:
3.5 MB
Formato:
Adobe Portable Document Format
Descripción:
Adrimonge.tésis-2.pdf
Cargando...
Miniatura
Nombre:
tablas1.pdf
Tamaño:
24.93 KB
Formato:
Adobe Portable Document Format
Descripción:
Adrimonge.tablas1-3.pdf
Cargando...
Miniatura
Nombre:
cuadros de datos respaldo Amonge.pdf
Tamaño:
224.52 KB
Formato:
Adobe Portable Document Format
Descripción:
Adrimonge.cuadros-4.pdf
Bloque de licencias
Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
license.txt
Tamaño:
1.42 KB
Formato:
Item-specific license agreed upon to submission
Descripción: