Estudio comparativo de hormigón mejorado con fibras de Tereftalato de polietileno (pet) y hormigón normal en el diseño de pavimento rígido de la calle Manuela de Garaicoa (av. Las iguanas) desde ecocity hasta: replica del colegio Simón Bolivar km14 vía a Daule (tramo 1) de 1.5 km de longitud

dc.contributor.authorRodriguez Merchan, Michelle Paola
dc.contributor.authorSumba Cordero, Cristhian Florencio
dc.contributor.tutorStay Coello David Omar
dc.date.accessioned2021-11-25T20:51:33Z
dc.date.available2021-11-25T20:51:33Z
dc.date.issued2021-10
dc.descriptionpdfes_ES
dc.description.abstractEl presente estudio tiene como finalidad la comparación entre el hormigón convencional y un hormigón con fibras PET de 5cm de largo, para este proyecto se consideró un módulo de rotura de 4.2MPa, se realizó el análisis del comportamiento a los 7, 14, y 28 días del hormigón convencional y mejorado mediante cilindros y vigas, los cuales fueron evaluados a flexión y compresión respectivamente. Se pudo observar que a los 28 días los dos diseños alcanzaron su resistencia requerida con la observación que en el ensayo de compresión el hormigón convencional obtuvo mayor resistencia en comparación al convencional, mientras que a flexión el hormigón mejorado con fibras PET obtuvo mayor resistencia que el hormigón convencional. Se realizó el diseño del pavimento rígido para el hormigón convencional y el hormigón mejorado con fibras PET, se llegó a la conclusión que pese al incremento de su resistencia de diseño al utilizar fibras PET no se obtuvo variación en los espesores de losa, debido a los valores de módulo de rotura y elasticidad del concreto los cuales fueron similares para el hormigón convencional y mejorado. Esta propuesta surge debido a la necesidad de concientizar acerca de la contaminación producida al medio ambiente en el proceso de elaboración de hormigones, lo cual se optó por utilizar el plástico PET, este se puede conseguir fácilmente mediante la recolección de botellas.es_ES
dc.description.abstractThe purpose of this study is to compare conventional concrete and a concrete with 5cm long PET fibers, for this project a breaking modulus of 4.2MPa was considered, the behavior analysis was carried out at 7, 14, and 28 days of conventional and improved concrete by means of cylinders and beams, which were evaluated in flexión and compression respectively. It was observed that at 28 days the two designs reached their required strength with the observation that in the compression test the conventional concrete obtained greater resistance compared to the conventional one, while in bending the concrete improved with PET fibers obtained greater resistance than the conventional concrete. Conventional concrete. The rigid pavement design was carried out for conventional concrete and improved concrete with PET fibers, it was concluded that despite the increase in its design resistance when using PET fibers, no variation was obtained in the slab thicknesses, due to the values of modulus of rupture and elasticity of concrete, which were similar for conventional and improved concrete. This proposal arises due to the need to raise awareness about the pollution produced to the environment in the process of making concrete, which was chosen to use PET plastic; this can be easily achieved by collecting bottleses_ES
dc.identifier.urihttp://repositorio.ug.edu.ec/handle/redug/56650
dc.language.isospaes_ES
dc.publisherUniversidad de Guayaquil - Facultad de Ciencias Matemáticas y Físicas - Carrera Ingeniería Civiles_ES
dc.relation.ispartofseries;1 Digital
dc.rightsopenAccesses_ES
dc.subjectPETes_ES
dc.subjectHORMIGÓNes_ES
dc.subjectCOMPARATIVOes_ES
dc.subjectPAVIMENTO RÍGIDOes_ES
dc.titleEstudio comparativo de hormigón mejorado con fibras de Tereftalato de polietileno (pet) y hormigón normal en el diseño de pavimento rígido de la calle Manuela de Garaicoa (av. Las iguanas) desde ecocity hasta: replica del colegio Simón Bolivar km14 vía a Daule (tramo 1) de 1.5 km de longitudes_ES
dc.typeThesises_ES
Archivos
Bloque original
Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
BMAT-V 134-2021-Ing. CIVIL - RODRIGUEZ MERCHAN MICHELLE PAOLA - SUMBA CORDERO CRISTHIAN FLORENCIO.pdf
Tamaño:
3.46 MB
Formato:
Adobe Portable Document Format
Descripción:
UG-FCMF-B.ING.CIVIL-V 134-2021
Bloque de licencias
Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
license.txt
Tamaño:
902 B
Formato:
Item-specific license agreed upon to submission
Descripción: